Results 1 - 20 de 2.035
Filter
1.
J Vasc Nurs ; 42(1): 44-52, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38555177

ABSTRACT

PROBLEM: Arterial blood gasses (ABGs) account for an estimated 10-20% of all costs during an ICU stay. Non-clinically indicated ABGs increased costs of care, lengths of stay, ventilator days, and line days, increasing the risk of adverse outcomes in already vulnerable critically ill patients. A cardiac surgery intensive care unit (CSICU) within a large urban mid-Atlantic academic medical center accounted for 31% of the entire institution's ABG analyses between 2018-2019, was identified as a top utilizer due to inappropriate ordering practices compared to current guidelines. PURPOSE: The purpose of this quality improvement project was to implement an algorithm using evidence-based guidelines that identified appropriate standardized clinical indications for ABGs, with the intention of reducing non-clinically indicated blood gas analyses orders within the CSICU. Anticipated outcomes of this practice change included decreasing the total volume of ABGs sent, resulting in reduced costs of care, lengths of stay, and improved morbidity and mortality rates. METHODS: An evidence-based ABG indication algorithm was created focusing on acute changes in oxygenation, ventilation, acid base balance; changes in hemodynamics, post-operative baseline, and for patient ABGs to correlate with extra-corporeal membranous oxygenation values. Routine ABGs for monitoring were eliminated. Implementation occurred over fourteen-weeks in the fall of 2020 following staff and provider education. Training emphasized the use of non-invasive monitoring such as pulse-oximetry and capnography. Compliance and gross laboratory totals and indications were obtained from weekly auditing. RESULTS: There was an 8.8% reduction in ABGs obtained and 32% decrease in ABGs per patient day. The most common indications were extra-corporeal membranous oxygenation (ECMO)-correlated ABGs, post-operative, and changes in oxygenation and/or ventilation; 7.8% were non-indicated. CONCLUSIONS: Implementation of an ABG indication algorithm resulted in fewer ABGs sent, mostly due to a reduction in routine monitoring, and ABGs were more likely to be clinically indicated in response to an acute concern. Implementing an ABG indication algorithm is safe, feasible, and can lead to significant cost reductions for the institution.


Subject(s)
Cardiac Surgical Procedures , Oximetry , Humans , Blood Gas Analysis/methods , Intensive Care Units , Hemodynamics
2.
Sci Rep ; 14(1): 5194, 2024 03 02.
Article in English | MEDLINE | ID: mdl-38431760

ABSTRACT

The study aims to assess the accuracy of the arterial blood gas (ABG) analysis in measuring hemoglobin, potassium, sodium, and glucose concentrations in comparison to standard venous blood analysis among patients diagnosed with chronic obstructive pulmonary disease (COPD). From January to March 2023, results of ABG analysis and simultaneous venous blood sampling among patients with COPD were retrospectively compared, without any intervention being applied between the two methods. The differences in hemoglobin, potassium, sodium, and glucose concentrations were assessed using a statistical software program (R software). There were significant differences in the mean concentrations of hemoglobin (p < 0.001), potassium (p < 0.001), and sodium (p = 0.001) between the results from ABG and standard venous blood analysis. However, the magnitude of the difference was within the total error allowance (TEa) of the United States of Clinical Laboratory Improvement Amendments (US-CLIA). As for the innovatively studied glucose concentrations, a statistically significant difference between the results obtained from ABG (7.8 ± 3.00) mmol·L-1 and venous blood (6.72 ± 2.44) mmol·L-1 was noted (p < 0.001), with the difference exceeding the TEa of US-CLIA. A linear relationship between venous blood glucose and ABG was obtained: venous blood glucose (mmol·L-1) = - 0.487 + 0.923 × ABG glucose (mmol·L-1), with R2 of 0.882. The hemoglobin, potassium, and sodium concentrations in ABG were reliable for guiding treatment in managing COPD emergencies. However, the ABG analysis of glucose was significantly higher as compared to venous blood glucose, and there was a positive correlation between the two methods. Thus, a linear regression equation in this study combined with ABG analysis could be helpful in quickly estimating venous blood glucose during COPD emergency treatment before the standard venous blood glucose was available from the medical laboratory.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Sodium , Humans , Glucose , Blood Glucose , Potassium , Retrospective Studies , Blood Gas Analysis/methods , Hemoglobins/analysis
3.
Nurs Stand ; 39(3): 40-43, 2024 03 06.
Article in English | MEDLINE | ID: mdl-38312004

ABSTRACT

Arterial blood gas (ABG) analysis is a fundamental skill in healthcare practice, particularly when caring for acutely unwell or deteriorating patients. It can be useful in the assessment of patients' acid-base balance and gas exchange, thereby informing appropriate care and management. However, many nurses find interpreting ABG results challenging. This article outlines a simplified approach to ABG analysis using three main values - pH, partial pressure of carbon dioxide and bicarbonate - and applying the RoMe ('Respiratory opposite, Metabolic equal') technique. It also provides brief descriptions of selected acid-base imbalances and explains how to identify whether these are uncompensated, partially compensated or fully compensated.


Subject(s)
Bicarbonates , Carbon Dioxide , Humans , Rome , Blood Gas Analysis/methods
4.
J Clin Anesth ; 94: 111406, 2024 06.
Article in English | MEDLINE | ID: mdl-38325249

ABSTRACT

STUDY OBJECTIVE: Protocols are used in intensive care and emergency settings to limit the use of oxygen. However, in pediatric anesthesiology, such protocols do not exist. This study aimed to investigate the administration of oxygen during pediatric general anesthesia and related these values to PaO2, SpO2 and SaO2. DESIGN: Retrospective observational study. SETTING: Tertiary pediatric academic hospital, from June 2017 to August 2020. PATIENTS: Patients aged 0-18 years who underwent general anesthesia for a diagnostic or surgical procedure with tracheal intubation and an arterial catheter for regular blood withdrawal were included. Patients on cardiopulmonary bypass or those with missing data were excluded. Electronic charts were reviewed for patient characteristics, type of surgery, arterial blood gas analyses, and oxygenation management. INTERVENTIONS: No interventions were done. MEASUREMENTS: Primary outcome defined as FiO2, PaO2 and SpO2 values were interpreted using descriptive analyses, and the correlation between PaO2 and FiO2 was determined using the weighted Spearman correlation coefficient. MAIN RESULTS: Data of 493 cases were obtained. Of these, 267 were excluded for various reasons. Finally, 226 cases with a total of 645 samples were analyzed. The median FiO2 was 36% (IQR 31 to 43), with a range from 20% to 97%, and the median PaO2 was 23.6 kPa (IQR 18.6 to 28.1); 177 mmHg (IQR 140 to 211). The median SpO2 level was 99% (IQR 98 to 100%). The study showed a moderately positive association between PaO2 and FiO2 (r = 0.52, p < 0.001). 574 of 645 samples (89%) contained a PaO2 higher than 13.3 kPa; 100 mmHg. CONCLUSIONS: Oxygen administration during general pediatric anesthesia is barely regulated. Hyperoxemia is observed intraoperatively in approximately 90% of cases. Future research should focus on outcomes related to hyperoxemia.


Subject(s)
Oximetry , Oxygen , Child , Humans , Anesthesia, General/adverse effects , Blood Gas Analysis/methods , Critical Care , Oximetry/methods , Retrospective Studies
5.
Diagnosis (Berl) ; 11(1): 91-96, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37665244

ABSTRACT

OBJECTIVES: There is limited information on the influence of collecting small amounts of blood on the quality of blood gas analysis. Therefore, the purpose of this study was to investigate the effects of different degrees of underfilling of syringes on test results of venous blood gas analysis. METHODS: Venous blood was collected by venipuncture from 19 healthcare workers in three 1.0 mL syringes for blood gas analysis, by manually aspirating different volumes of blood (i.e., 1.0, 0.5 and 0.25 mL). Routine blood gas analysis was then immediately performed with GEM Premier 5,000. The results of the two underfilled syringes were compared with those of the reference syringe filled with appropriate blood volume. RESULTS: The values of most assayed parameters did not differ significantly in the two underfilled syringes. Statistically significant variations were found for lactate, hematocrit and total hemoglobin, the values of which gradually increased as the fill volume diminished, as well as for sodium concentration, which decreased in both insufficiently filled blood gas syringes. The bias was clinically meaningful for lactate in syringe filled with 0.25 mL of blood, and for hematocrit, total hemoglobin and sodium in both syringes containing 0.5 and 0.25 mL of blood. CONCLUSIONS: Collection of smaller volumes of venous blood than the specified filling volume in blood gas syringes may have an effect on the quality of some test results, namely lactate, hematocrit, total hemoglobin and sodium. Specific indications must be given for standardizing the volume of blood to be collected within these syringes.


Subject(s)
Lactic Acid , Syringes , Humans , Blood Gas Analysis/methods , Sodium , Hemoglobins
6.
Int J Lab Hematol ; 45(5): 678-684, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37190850

ABSTRACT

INTRODUCTION: Point of care (POC) analyzers are an integral part of the patient care. Transfuse can be an emergency decision, not being a benign act, it is necessary to ensure that the hemoglobin value measured by the POC are comparable with the reference analyzer. The objective is to compare the analytical performance of three POCs: ABL800 Flex, Hemocue and iSTAT and a central laboratory analyzer: XN-10 and the impact on the transfusion decision. METHODS: An in vitro study was performed in 50 patients for whom a hemogram had been prescribed on the XN-10, the hemoglobin determination was performed in parallel on the three POCs. Then, retrospective study was performed to compare the hemoglobin values returned for matched samples in routine practice, 5505 for ABL800 Flex, 55 for Hemocue and 70 for iSTAT were analyzed. RESULTS: In vitro study shows systematic biases in the measurement of hemoglobin between the different analyzers, overestimation for the ABL800 Flex and the Hemocue, underestimation for the iSTAT. These biases are accentuated in current practice for iSTAT but decreased for ABL800 Flex. In the transfusion decision range from 70 to 100 g/L, there were 8.6% of clinically discordant results between the reference method and ABL, 34.8% for Hemocue and 21.4% for iSTAT. CONCLUSION: In addition to systematic biases, many additional factors may be involved for variation in hemoglobin measurement with POC. Thus, in the case of urgent transfusion decisions, sending a hemogram on a central laboratory analyzer seems to be essential, while being compatible with a life-threatening emergency.


Subject(s)
Hematologic Tests , Point-of-Care Testing , Humans , Retrospective Studies , Blood Gas Analysis/methods , Point-of-Care Systems , Hemoglobins/analysis
7.
Clin Chem Lab Med ; 61(10): 1740-1749, 2023 09 26.
Article in English | MEDLINE | ID: mdl-37078234

ABSTRACT

OBJECTIVES: The objective of our study is to evaluate the effect of storage temperature and time to analysis on arterial blood gas parameters in order to extend the CLSI recommendations. METHODS: Stability of 12 parameters (pH, pCO2, pO2, Na+, K+, Ca2+, glucose, lactate, hemoglobin, oxyhemoglobin, carboxyhemoglobin, methemoglobin) measured by GEM PREMIER™ 5000 blood gas analyzer was studied at room temperature and at +4 °C (52 patients). The storage times were 30, 45, 60, 90 and 120 min. Stability was evaluated on the difference from baseline, the difference from the analyte-specific measurement uncertainty applied to the baseline value, and the impact of the variation on the clinical interpretation. RESULTS: At room temperature, all parameters except the lactate remained stable for at least 60 min. A statistically significant difference was observed for pH at T45 and T60 and for pCO2 at T60 without modification of clinical interpretation. For lactate, clinical interpretation was modified from T45 and values were outside the range of acceptability defined by the measurement uncertainty. All parameters except pO2 remained stable for at least 120 min at +4 °C. CONCLUSIONS: A one-hour transport at room temperature is compatible with the performance of all the analyses studied except lactate. If the delay exceeds 30 min, the sample should be placed at +4 °C for lactate measurement. If the samples are stored in ice, it is important to note that the pO2 cannot be interpreted.


Subject(s)
Blood Glucose , Carboxyhemoglobin , Humans , Carboxyhemoglobin/analysis , Blood Glucose/analysis , Glucose , Lactic Acid , Temperature , Hemoglobins/analysis , Blood Gas Analysis/methods , Electrolytes , Sodium , Ions , Hydrogen-Ion Concentration , Gases
8.
Clin Chem Lab Med ; 61(10): 1750-1759, 2023 09 26.
Article in English | MEDLINE | ID: mdl-37015069

ABSTRACT

OBJECTIVES: Human blood gas stability data is limited to small sample sizes and questionable statistical techniques. We sought to determine the stability of blood gases under room temperature and slushed iced conditions in patients using survival analyses. METHODS: Whole blood samples from ∼200 patients were stored in plastic syringes and kept at room temperature (22-24 °C) or in slushed ice (0.1-0.2 °C) before analysis. Arterial and venous pO2 (15-150 mmHg), pCO2 (16-72 mmHg), pH (6.73-7.52), and the CO-oximetry panel [total hemoglobin (5.4-19.3 g/dL), percentages of oxyhemoglobin (O2Hb%, 20-99%), carboxyhemoglobin (COHb, 0.1-5.4%) and methemoglobin (MetHb, 0.2-4.6%)], were measured over 5-time points. The Royal College of Pathologists of Australasia's (RCPA's) criteria determined analyte instability. Survival analyses identified storage times at which 5% of the samples for various analytes became unstable. RESULTS: COHb and MetHb were stable up to 3 h in slushed ice and at room temperature; pCO2, pH was stable at room temperature for about 60 min and 3 h in slushed ice. Slushed ice shortened the storage time before pO2 became unstable (from 40 to 20 min), and the instability increased when baseline pO2 was ≥60 mmHg. The storage time for pO2, pCO2, pH, and CO-oximetry, when measured together, were limited by the pO2. CONCLUSIONS: When assessing pO2 in plastic syringes, samples kept in slushed ice harm their stability. For simplicity's sake, the data support storage times for blood gas and CO-oximetry panels of up to 40 min at room temperature if following RCPA guidelines.


Subject(s)
Ice , Oximetry , Humans , Temperature , Blood Gas Analysis/methods , Plastics , Gases , Oxygen , Carbon Dioxide , Hydrogen-Ion Concentration
9.
Am J Emerg Med ; 66: 129-134, 2023 04.
Article in English | MEDLINE | ID: mdl-36753928

ABSTRACT

INTRODUCTION: The Roth score is an alternative strategy to estimate oxygen saturation by using a simple verbal test. We designed this clinical study to assess the validity of the Roth score (Spanish version) as a screening test for hypoxemia. A secondary objective was to evaluate the agreement and consistency between the oxygen saturation obtained via pulse oximetry (SpO2) and arterial blood gas test (SaO2). METHODS: An observational study was conducted in two hospital emergency departments. Adult patients who underwent arterial blood gas tests were included in the analysis. Pulse oximetry values were determined, and the Roth score was applied in the Spanish language. The validity of the Roth score was assessed in terms of sensitivity and specificity by creating ROC curves and by calculating the area under the curve (AUC) for SpO2, SaO2, and oxygen pressure in the arterial blood (PaO2). Agreement between SpO2 and SaO2 values was assessed by using the intraclass correlation coefficient (ICC), and consistency between both measures was calculated by following the method of Bland and Altman. RESULTS: The ROC curve models of the Roth score results that were obtained for SaO2 < 90%, ≤92%, and < 95% had AUCs of 0.574, 0.462, and 0.543, respectively, for the highest number that was obtained in the test, as well as AUCs of 0.403, 0.376, and 0.495, respectively, for the maximum time that was used. The AUCs for PaO2 ≤ 60, ≤70, and ≤80 mmHg were 0.534, 0.568, and 0.512, respectively, for the maximum number that was obtained in the test, as well as AUCs of 0.521, 0.515, and 0.519, respectively, for the maximum time that was spent. The ICC between SaO2 and SpO2 was 0.817 (p < 0.001); additionally, the mean difference between the two measurements was -0.55. CONCLUSION: The Roth score performed in Spanish is not a valid test for hypoxemia screening. There is sufficient agreement and consistency between SaO2 and SpO2 measurements.


Subject(s)
Hypoxia , Oximetry , Adult , Humans , Oximetry/methods , Hypoxia/diagnosis , Oxygen , Blood Gas Analysis/methods , Sensitivity and Specificity
10.
Hemodial Int ; 27(2): 105-111, 2023 04.
Article in English | MEDLINE | ID: mdl-36788419

ABSTRACT

INTRODUCTION: We evaluated the effects of pre-analytical care on total carbon dioxide (tCO2 ) in hemodialysis patients, as calculated by blood gas analysis (ctCO2 ) or measured by an enzymatic assay (mtCO2 ). METHODS: Blood samples were collected via vascular access before dialysis sessions. For blood gas analysis, eight aliquots were collected, refrigerated or non-refrigerated, and analyzed at 0, 4, 8, and 24 h after collection. A blood sample was then collected for the enzymatic method and distributed into 14 aliquots. Half of the aliquots were refrigerated. The samples analyzed at time point 0 were centrifuged immediately. The remaining aliquots of both the refrigerated and non-refrigerated clusters were centrifuged before storage. Samples were analyzed at 4, 8, and 24 h post-collection. FINDINGS: By blood gas analysis, no significant change was found in bicarbonate values over time, either in the non-refrigerated or refrigerated samples. ctCO2 values during the experiment showed a minor but statistically significant increase of questionable clinical relevance in both non-refrigerated and refrigerated aliquots. In the enzymatic assay, the reduction in mtCO2 levels during the experiment was negligible. The median absolute reductions at the end of the experiment were 1.77, 1.21, 1.04, and 1.12 mmol/L for the non-centrifuged/non-refrigerated, centrifuged/non-refrigerated, non-centrifuged/refrigerated, and centrifuged/refrigerated aliquots, respectively. DISCUSSION: Our results suggest that measured or calculated tCO2 levels of capped and cooled samples are adequate for analyzing the acid-base status of hemodialysis patients, even when such determination is not performed immediately after collection.


Subject(s)
Acidosis , Renal Dialysis , Humans , Carbon Dioxide , Blood Gas Analysis/methods , Bicarbonates
11.
Clin Biochem ; 115: 107-111, 2023 May.
Article in English | MEDLINE | ID: mdl-36126745

ABSTRACT

Accurate reporting of blood gas samples is dependent upon following proper preanalytical sample handling requirements though there is variation for sample acceptability criteria across institutions. We examined five common sample types (arterial, venous, umbilical arterial, umbilical venous and capillary) stored at either room temperature or on crushed ice in a time series (0, 15, 30, 45, 60, 90, 180, 240 min) and applied local regulatory and/or institutional allowable performance limits to determine the need for cold preservation and/or maximum stability time for pH, pO2, pCO2, glucose, lactate, sodium, potassium, chloride, and ionized calcium where applicable in each sample type. Although changes in sample pO2 and/or lactate values were responsible, in part or in whole, for surpassing the allowable limits in nearly all sample types analyzed, this was not uniformly observed across sample types within the typical time limits that are referenced in literature. Furthermore, we demonstrated that cold preservation may not ubiquitously provide longer stability for blood gas specimens and this is dependent on the sample type and analyte in question. Nevertheless, these results demonstrate the known instability of pO2 and lactate and suggest that it may be possible to simplify the monitoring of preanalytical conditions by first evaluating pO2 and lactate in patient blood gas samples if applicable.


Subject(s)
Electrolytes , Potassium , Humans , Blood Gas Analysis/methods , Sodium , Lactic Acid
12.
Perfusion ; 38(4): 740-746, 2023 05.
Article in English | MEDLINE | ID: mdl-35285344

ABSTRACT

INTRODUCTION: Accurate and precise management of blood gas parameters during cardiopulmonary bypass (CPB) is crucial to patient care and outcome. This study compares the data provided by Livanova B-Capta, Terumo CDI500, and Spectrum Medical M4 with the results from a gold standard blood gas analyzer to test accuracy. METHODS: All three continuous blood gas monitoring (CBGM) devices were used simultaneously during CPB on one dedicated HLM. Arterial and venous blood samples of 40 adult patients who underwent elective cardiac surgery with CPB were taken from the CPB circuit. RESULTS: Pre- and post-alignment deviation in percentages are compared with CLIA guidelines. B-Capta data reveals that the deviation pre-alignment is small and within the CLIA threshold for all parameters. Pre-alignment data for CDI 500 is within CLIA threshold for SvO2 and PaO2. The pre-alignment data for the M4 exceeds the CLIA thresholds for all parameters. Post-alignment data for B-Capta and CDI 500 reveals an accurate agreement for Hb and Hct and strong agreement for PaO2. All values for B-Capta and CDI 500 are within CLIA threshold values except for SvO2. Post-alignment the M4 exceeded the CLIA threshold value only for PaO2. CONCLUSION: B-Capta is the only CBGM device that operates within the CLIA guidelines and is in agreement with laboratory values prior to alignment.


Subject(s)
Cardiac Surgical Procedures , Cardiopulmonary Bypass , Adult , Humans , Cardiopulmonary Bypass/methods , Blood Gas Analysis/methods , Monitoring, Physiologic/methods , Oxygen
13.
Clin Biochem ; 111: 60-65, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36279904

ABSTRACT

BACKGROUND: Blood gas analyzers employing glucose-oxidase biosensors under-recover glucose when pO2 is low. The manufacturer of the GEM®Premier™ series of analyzers introduced an algorithm to detect specimens at risk of low pO2 interference. We investigated the reliability of this algorithm. METHODS: Whole blood specimens were tested by GEM®Premier™ 4000 (GEM 4000) and 5000 (GEM 5000). Specimens with an incalculable ("incalc") error code for glucose result or that had a glucose ≥ 20 mmol/L were retested on a second analyzer of the same type within 5 min over the course of 30 months in 5 hospitals in Calgary, Alberta. Discordant retests were defined as either: 1) paired numeric results with a difference >10 %, or 2) an "incalc" code that yielded a numeric result upon retesting. Glucose recovery in relation to pO2 level was assessed by comparing specimens experimentally depleted of pO2 between GEM 5000 and a laboratory analyzer (Siemens Vista®). RESULTS: Of 1,776 glucose tests repeated on the GEM 5000 or 1,544 on GEM 4000, 10% were discordant. GEM 5000 produced twice as many discordant numeric retests versus the GEM 4000 [5.9% (98/1,651) vs 2.7% (38/1,391)]. The majority of "incalc" error codes repeated with a numeric glucose result on both GEM analyzers [(79.7% (122/153) vs 75.2% (94/125)]. Among specimens experimentally depleted of pO2, the GEM 5000 under-recovered glucose by up to 30% compared to the Siemens Vista and were not flagged by an "incalc" code. CONCLUSIONS: The algorithm in the GEM®PremierTM series of analyzers that flags specimens at risk for glucose under-recovery due to low pO2 does not reliably detect specimens at risk for glucose under-recovery.


Subject(s)
Glucose , Oxygen , Humans , Partial Pressure , Reproducibility of Results , Point-of-Care Systems , Blood Gas Analysis/methods , Blood Glucose
14.
Paediatr Anaesth ; 33(2): 107-113, 2023 02.
Article in English | MEDLINE | ID: mdl-36178754

ABSTRACT

INTRODUCTION: We aimed to evaluate the interchangeability of sodium, potassium, hemoglobin, and hematocrit measurement between the blood gas analyzers and laboratory automatic analyzers results. METHODS: This was a retrospective cross-sectional study. The results of 1927 paired samples analyzed simultaneously with the blood gas analyzer and the laboratory automatic analyzer were compared. The Bland-Altman and Cohen's kappa statistic detected the agreement between the two analyses. RESULTS: The limits of agreement (±1.96 standard deviation of the mean difference) were -11.1 to 20.3 for sodium, -1.9 to 0.5 for potassium, -16.1 to 12.9 for hematocrit, and -5.0 to 4.0 for hemoglobin. Agreement between the two analyses was not acceptable within the defined clinically acceptable limits. In addition, none of the kappa values were higher than 0.60, which highlights the lack of agreement between the two analyzers. CONCLUSION: The blood gas analyzers and laboratory automatic analyzers results cannot be used interchangeably.


Subject(s)
Electrolytes , Point-of-Care Systems , Humans , Child , Retrospective Studies , Cross-Sectional Studies , Blood Gas Analysis/methods , Potassium , Sodium , Hemoglobins/analysis
15.
Vet Clin Pathol ; 52(1): 22-29, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36573472

ABSTRACT

BACKGROUND: Manufacturers of point-of-care (POC) analyzers recommend immediate processing and anaerobic collection of blood samples. However, it is not uncommon for clinical scenarios to result in delayed sample processing or room air exposure that could impact the test results. OBJECTIVE: To investigate the effect of time delay and sample storage method on key POC analytes in canine venous blood samples processed with an Element POC analyzer. METHODS: Blood gas analysis was performed on venous blood samples at times 0 (T0), 15, 30, and 60 minutes after sampling using three different storage methods: preheparinized plastic syringes and two different lithium heparin tubes. To determine clinical relevance, results were compared with allowable total error of the respective parameter. Significance was set at P < 0.05. RESULTS: Significant differences between the three storage methods at baseline were found for partial pressure of carbon dioxide (PCO2 ), partial pressure of oxygen (PO2 ), base excess, and total hemoglobin. No significant differences up to T60 were found within collection methods for actual bicarbonate (HCO3 - ), base excess, sodium, potassium, chloride, ionized calcium (iCa), glucose, and BUN. Significant differences within collection methods were found after T0 for creatinine, after 15 minutes for lactate, and after 30 minutes for pH and hematocrit. No significant differences were found for PO2 in samples stored in preheparinized plastic syringes at any time point. CONCLUSIONS: These results suggest that HCO3 - , sodium, potassium, chloride, iCa, glucose, and BUN are comparable within the three storage methods for up to 60 minutes after sampling without resulting in clinically relevant changes.


Subject(s)
Chlorides , Point-of-Care Systems , Animals , Dogs , Blood Gas Analysis/methods , Blood Gas Analysis/veterinary , Potassium , Sodium , Glucose , Blood Preservation/veterinary , Plastics
16.
Rev. urug. cardiol ; 38(1): e403, 2023. ilus, tab
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1450410

ABSTRACT

Introducción: la monitorización hemodinámica constituye un conjunto de técnicas y parámetros que permiten valo rar si la función cardiovascular es la adecuada para mantener la perfusión y la oxigenación tisular que permita sa tisfacer las demandas metabólicas del organismo, valorar el estado y el comportamiento del sistema cardiovascular, orientando sobre la mejor estrategia terapéutica. La presente revisión busca proporcionar una descripción general e integrada de las diferentes técnicas de monitorización, así como aspectos fisiológicos relevantes para su entendi miento y empleo terapéutico. La monitorización hemodinámica acompañada de un adecuado conocimiento de la fisiología cardiovascular permite determinar el estado del sistema cardiovascular, la condición hemodinámica del paciente y la estrategia terapéutica requerida. Su interpretación debe partir de la integración y la correlación de diversos parámetros hemodinámicos.


Introduction: hemodynamic monitoring is a set of techniques and parameters that allow evaluating whether cardio vascular function is adequate to maintain tissue perfusion and oxygenation to satisfy metabolic demands of the or ganism, assess the condition and behavior of the cardiovascular system, providing guidance on the best therapeutic strategy. This review seeks to provide a general and integrated description of the different monitoring techniques, as well as physiological aspects relevant to their understanding and therapeutic use. Hemodynamic monitoring accompanied by an adequate knowledge of cardiovascular physiology allows to determine the state of the cardiovascular system, hemodynamic condition of the patient and therapeutic strategy required, its interpretation must start from the integration and correlation of different hemodynamic parameters.


Introdução: a monitorização hemodinâmica constitui um conjunto de técnicas e parâmetros que permitem avaliar se a função cardiovascular é adequada para manter a perfusão e oxigenação tecidual que permite satisfazer as exi gências metabólicas do organismo, avaliar o estado e comportamento do sistema cardiovascular, orientando sobre a melhor estratégia terapêutica. Esta revisão procura fornecer uma descrição geral e integrada das diferentes técnicas de monitorização, bem como aspectos fisiológicos relevantes para a sua compreensão e utilização terapêutica. A monitorização hemodinâmica acompanhada de um conhecimento adequado da fisiologia cardiovascular permite determinar o estado do sistema cardiovascular, a condição hemodinâmica do doente e a estratégia terapêutica neces sária, a sua interpretação deve partir da integração e correlação de vários parâmetros hemodinâmicos.


Subject(s)
Humans , Cardiovascular Physiological Phenomena , Critical Illness/therapy , Hemodynamic Monitoring/methods , Blood Gas Analysis/methods , Echocardiography/methods , Critical Care/methods
17.
J Clin Lab Anal ; 36(11): e24736, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36250221

ABSTRACT

BACKGROUND: To evaluate the accuracy and stability of arterial blood gas (ABG) results by comparison with venous measurements from routine blood tests, and to compare the accuracy and performance of two sampling syringes, pre-heparinized syringe (PHS) and disposable arterial blood syringe (DABS), in ABG analysis. METHODS: We retrospectively analyzed the practical use of PHS and DABS in collecting ABG samples, involving 500 and 400 patients, respectively. For each patient, in addition to the ABG sample, a venous blood sample was also collected using a venous blood collection tube (VBCT) and used for routine blood tests. Accordingly, patients were referred to as the PHS + VBCT group and DABS + VBCT group. The correlation between arterial and venous values of each blood parameter in each group was evaluated using the interclass correlation coefficient (ICC). Bland-Altman was performed to evaluate the agreement between arterial and venous values and compare the performance of PHS and DABS in ABG sample collection. RESULTS: In the PHS + VBCT group, arterial K+ , Na+ , hemoglobin (Hb), and hematocrit (HCT) were 0.32 mmol/L, 2.90 mmol/L, 2.21 g/L, and 1.27% significantly lower their corresponding venous values while arterial Cl- was 7.60 mmol/L significantly higher than venous Cl- . In the DABS + VBCT group, arterial K+ and Na+ were 0.20 mmol/L and 1.19 mmol/L significantly lower while Cl- and HCT in arterial blood were 5.34 mmol/L and 0.66% significantly higher than their corresponding venous values. In both groups, arterial K+ , Na+ , Hb, and HCT values were highly consistent with their corresponding venous values, with all ICCs greater than 0.70, especially Hb and HCT. Bland-Altman analysis demonstrated that arterial K+ and Na+ were more consistent with venous counterparts in the DABS + VBCT group, with a narrower 95% limits of agreement than the PHS + VBCT group (K+ , -0.7-0.3 mmol/L vs. -1.1 to 0.5 mmol/L; Na+ , -5.8 to 3.4 mmol/L vs. -8.2 to 2.4 mmol/L). CONCLUSION: Arterial blood gas analysis of K+ , Na+ , Hb, and HCT using PHS or DABS for blood sampling is accurate and stable, especially DABS, which can provide clinicians with fast and reliable blood gas results.


Subject(s)
Blood Gas Analysis , Blood Specimen Collection , Humans , Blood Gas Analysis/methods , Blood Specimen Collection/instrumentation , Hemoglobins , Retrospective Studies , Veins
18.
Acta Anaesthesiol Scand ; 66(10): 1247-1256, 2022 11.
Article in English | MEDLINE | ID: mdl-36054137

ABSTRACT

BACKGROUND: Multiple studies have investigated the association between hyperoxaemia following cardiac arrest (CA) and unfavourable outcomes; however, they have yielded inconsistent results. Most previous studies quantified oxygen exposure without considering its timing or duration. We investigated the relationship between unfavourable outcomes and supranormal arterial oxygen tension (PaO2 ), commonly defined as PaO2 > 100 mmHg, at specific time intervals within 24 h following CA. METHODS: This retrospective observational study included 838 adult non-traumatic patients with CA. The first 24 h following CA were divided into four 6-h time intervals, and the first 6-h period was further divided into three 2-h segments. Multivariable logistic regression analyses were conducted to assess associations of the highest PaO2 and time-weighted average PaO2 (TWA-PaO2 ) values at each time interval with unfavourable outcomes at hospital discharge (cerebral performance categories 3-5). RESULTS: The highest PaO2 (p = .028) and TWA-PaO2 (p = .022) values during the 0-6-h time interval were significantly associated with unfavourable outcomes, whereas those at time intervals beyond 6 h were not. The association was the strongest at supranormal PaO2 values within the 0-2-h time interval, becoming significant at PaO2 values ≥ 150 mmHg. During the first 6 h, longer time spent at ≥150 mmHg of PaO2 was associated with an increased risk of unfavourable outcomes (p = .038). The results were consistent across several sensitivity analyses. CONCLUSION: Supranormal PaO2 during but not after the first 6 h following cardiac arrest was independently associated with unfavourable outcomes.


Subject(s)
Heart Arrest , Hyperoxia , Adult , Humans , Hospital Mortality , Oxygen , Heart Arrest/complications , Heart Arrest/therapy , Blood Gas Analysis/methods , Retrospective Studies
19.
J Vet Sci ; 23(4): e60, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35920124

ABSTRACT

BACKGROUND: A definite diagnosis should be made in the bovine practice field, however, it was difficult to perform laboratory analysis immediately. Currently, three types of portable blood gas analyzers are available in Korea. OBJECTIVES: This study aimed to evaluate the correlations among these three analyzers. METHODS: Seventy-two plasma samples from Holstein-Friesian cows were used for blood gas analysis, and three instruments (EDAN i15 Vet, VETSCAN i-STAT, and EPOC) were operated simultaneously. Moreover, plasma calcium levels were compared between these portable analyzers and blood chemistry device, which is usually used in a laboratory environment. Pearson analysis was performed to confirm the correlation of each parameter produced with the three instruments and blood chemistry analyzer. RESULTS: As results, high correlation was observed in parameters of pH, pO2, potassium ion, ionized calcium, and glucose (p < 0.001, r > 0.7). In addition, pCO2 showed a moderate correlation among the three analyzers (p < 0.001, r > 0.5), and there was no correlation among all instruments for sodium ions. There was also a high correlation between ionized calcium from the three portable devices and total calcium from the biochemistry analyzer (p < 0.001, r > 0.9). CONCLUSIONS: In conclusion, there was a high correlation between results from the three different blood gas analyzers used in the bovine clinical field in Korea. Thus, a consistent diagnosis can be made even with different equipment if the operator is aware of the strengths and weaknesses of each piece of equipment and operates it properly.


Subject(s)
Calcium , Point-of-Care Systems , Animals , Blood Gas Analysis/methods , Blood Gas Analysis/veterinary , Cattle , Electrolytes , Female , Potassium
20.
Physiol Meas ; 43(9)2022 09 05.
Article in English | MEDLINE | ID: mdl-35959652

ABSTRACT

Objective.Noninvasive measurement of oxygen saturation (SpO2) using transmissive photoplethysmography (tPPG) is clinically accepted and widely employed. However, reflective photoplethysmography (rPPG)-currently present in smartwatches-has not become equally accepted, partially because the pathlengths of the red and infrared PPGs are patient-dependent. Thus, even the most popular 'Ratio of Modulation' (R) method requires patient-dependent calibration to reduce the errors in the measurement ofSpO2using rPPGs.Approach.In this paper, a correction factor or 'pathlength ratio'ßis introduced in an existing calibration-free algorithm that compensates the patient-dependent pathlength variations, and improved accuracy is obtained in the measurement ofSpO2using rPPGs. The proposed pathlength ratioßis derived through the analytical model of a rPPG signal. Using the new expression and data obtained from a human hypoxia study wherein arterial oxygen saturation values acquired through Blood Gas Analysis were employed as a reference,ßis determined.Main results.The results of the analysis show that a specific combination of theßand the measurements on the pulsating part of the natural logarithm of the red and infrared PPG signals yields a reduced root-mean-square error (RMSE). It is shown that the average RMSE in measuringSpO2values reduces to 1 %.Significance.The human hypoxia study data used for this work, obtained in a previous study, coversSpO2values in the range from 70 % to 100 %, and thus shows that the pathlength ratioßproposed here works well in the range of clinical interest. This work demonstrates that the calibration-free method applicable for transmission type PPGs can be extended to determineSpO2using reflective PPGs with the incorporation of the correction factorß. Our algorithm significantly reduces the number of parameters needed for the estimation, while keeping the RMSE below the clinically accepted 2 %.


Subject(s)
Oximetry , Photoplethysmography , Blood Gas Analysis/methods , Calibration , Humans , Hypoxia , Oximetry/methods , Oxygen/metabolism , Photoplethysmography/methods
SELECTION OF CITATIONS